CERBERUS-PRO Point Detectors
SMOKE DETECTORS
Scroll down the page for more details.
OH720

OP720

ASA OOH740

ASA OOHC740

THERMAL/HEAT DETECTORS
Scroll down the page for more details.
HI720

HI722

smoke detectors

Downloads
OH720 Multi-sensor smoke detector
Multi-sensor smoke detector consists of:
- Detector
- Dust cap to cover the detector for protection against dust during construction work
Function
- works according to the scattered light principle with one sensor, optical forward scattering
- Opto-electronic sampling chamber holds off disturbing extraneous light but optimally detects smoke particles
- an additional heat sensor increases the fire detector’s immunity to deceptive phenomena
- selectable detection behavior by different parameter sets
- immunity against transient false alarm causes
Application
- for the detection of flaming fires caused by the combustion of liquid and solid matters, as well as smoldering fires
- for reliable fire detection in environments with deceptive phenomena

Downloads
OP720 Smoke detector
Multi-sensor smoke detector consists of:
- Detector
- Dust cap to cover the detector for protection against dust during construction work
Function
- works according to the scattered light principle with one sensor, optical forward scattering
- Opto-electronic sampling chamber holds off disturbing extraneous light but optimally detects smoke particles
- selectable detection behavior by different parameter sets
Application
- for the detection of smoke-generating flaming and smoldering fires

Downloads
OOH740 Multi sensor smoke detector, ASA
Multi-sensor smoke detector consists of:
– Detector
– Dust cap to cover the detector for protection against dust during construction work
Function
– works according to the scattered light principle with two sensor, optical forward and backward scattering
– Opto-electronic sampling chamber holds off disturbing extraneous light but optimally detects smoke particles
– two additional heat sensors increase the fire detector’s immunity to deceptive phenomena
– software can be set to multi sensor smoke detector, as smoke detector or as heat detector
– selectable detection behavior by application-specific ASA parameter sets
Application
– for the early detection of flaming fires caused by the combustion of liquid and solid matters, as well as smoldering fires
– for reliable fire detection in environments with deceptive phenomena
– addressable or collective

Downloads
OOHC740 fire and CO detector, neural ASA
Multi-sensor smoke detector consists of:
– Detector
– Dust cap to cover the detector for protection against dust during construction work
Function
– works according to the scattered light principle with two sensor, optical forward and backward scattering
– Opto-electronic sampling chamber holds off disturbing extraneous light but optimally detects smoke particles
– two additional heat sensors and an additional CO sensor increase the fire detector’s immunity to deceptive phenomena and the response characteristics of the fire detector
– Technical ambient supervision: alarming when the temperature or the CO concentration threshold value is exceeded or undershot
– works with an electrochemical CO cell
– transmission of a CO concentration alarm on an independent technical CO alarm channel
– signal processing by the technical CO alarm channel independently of the CO signal processing for fire detection
– selectable detection behavior of the CO alarm channel, independent of ASA-parameter sets for fire detection
– selectable detection behavior by application-specific ASA parameter sets
Application
– for the very early detection of smoldering fires generating carbon monoxide (CO) (e.g. mattress fire in asylum)
– or the very early and reliable fire detection in environments with deceptive phenomena
– Environments with increased CO toxic risk, e.g. heating rooms, combustion plants, fermentation plants, car parks, automotive workshops, animal stalls, chemical labs or production sites
– addressable
Thermal/Heat detectors

Downloads
HI720 Heat detector (static+RoR)
Multi-sensor smoke detector consists of:
- Detector
- Dust cap to cover the detector for protection against dust during construction work
Function
- equipped with one heat sensor
- for high requirements
- certain response behavior with slow and fast temperature increases, also by depth
temperature - selectable detection behavior by different parameter sets
Application
- suitable in areas in which occur different environment temperatures
- where high dust or dirt developments or large humidity which can the impact of conventional alarm units to impair

Downloads
HI722 Heat detector (static)
Multi-sensor smoke detector consists of:
- Detector
- Dust cap to cover the detector for protection against dust during construction work
Function
- equipped with one heat sensor
- measures the ambient temperature, when the maximum temperature is exceeded the detector sends a danger signal to the fire control panel
Application
- suitable in areas in which temporary high variations in temperature arise
- where high dirt and heat fluctuation which can the impact of conventional alarm units to impair